Economical Residential Elevators Passenger Elevator

2016-04-07

Ceiling:As customized 

Side walls and rear wall:

Central panel:Etching mirror steel

Auxiliary panels:Hairline stainless Steel

Handrail:Hairline stainless steel

Floor:PVC/Marble

Small Machine Room
Loading PassengerLoading CapacitySpeedCar SizeShaft(Min.)Overhead HeightRise(Max.)
Passenger(Kg)(m/s)W*D*H(mm)W*D(mm)W*D(mm)HQ(Max.)(m)
64501.01100*1100*24001800*1800450045
86301.0-1.751400*1100*24002000*1800450095
108001.0-2.51400*1300*24002000*20004500120
1310001.0-3.01600*1500*24002200*22004500150
1612501.0-4.01950*1400*24002600*20504500180
2116001.0-4.01950*1750*24002600*24004500180
Machine Room less
Loading PassengerLoading CapacitySpeedCar SizeShaft(Min.)Overhead HeightRise(Max.)
Passenger(Kg)(m/s)W*D*H(mm)W*D(mm)W*D(mm)HQ(Max.)(m)
64501.01100*1100*24001800*1750450045
86301.0-1.751400*1100*24002250*1750450095
108001.0-2.51400*1300*24002250*18004500120
1310001.0-2.51600*1500*24002450*19504500150
1612501.0-2.51950*1400*24002950*18504500180
2116001.0-2.51950*1750*24002950*22004500180


                       
 
 
 
 
 
 
 
 
 
 
 
 
Safety function
Photocell protectionl  In the door open and shut period, infrared light that covers the whole door height is used to probe the door protection device of both the passengers and objects.
Designated stopl  If the elevator can not open the door in the destination floor out of some reason, the elevator will close the door and travel to the next designated floor.
Overload holding stopl  When the car is overload, the buzzer rings and stops the elevator in the same floor.
Anti-stall timer protectionl  The elevator stops operation due to slippery traction wire rope.
Start protection controll  If the elevator does not leave door zone with in the designated time after it gets started, it will stop the operation.
Inspection operationl  When the elevator enters into inspection operation, the car travels at inching running.
Fault self-diagnosisl  The controller can record 62 latest troubles so as to quickly remove the trouble and restore the elevator operation.
Repeated door closingl  If the elevator can not close the door due to certain obstacle or interference, the elevator will reopen or re-shut the door until sundries are eliminated.
Up/down over-run and final limit protectionl  The device can effectively prevent the elevator from surging to the top or knocking the bottom when it is out of control. It results in more safe and reliable elevator travel.
Down over-speed protection devicel  When the elevator downs 1.3 times higher than the rated speed, this device will automatically cut off control mains, stop the motor running. Safety tongs act to force the elevator stop in order to ensure the safety.
Upward over-speed protection devicel  When the elevator up speed is 1.3 times higher than rated speed, the device will automatically decelerate or brake the elevator.




加载中
  • QQ咨询
  • 电话咨询
  • +86-15957210986
  • +86-18367295962